your location:首页 > Services > Textiles & Clothing

Textiles & Clothing

EN15601902607 Personal Protective Mask Testing

Masks are divided into medical masks and non medical masks. The production types and requirements of masks vary. This article discusses that personal protective...

To get tested, look for Baijian!

consultation hotline :400-101-7153

Mobile/WhatsApp:15601902607

test details

EN15601902607 Personal Protective Mask TestingHow to apply for a report? What items need to be tested? We will conduct testing and evaluation in strict accordance with the standards. We can also provide personalized testing plans and reports according to your needs.

Masks are divided into medical masks and non medical masks. The production types and requirements of masks vary. This article discusses that personal protective masks should be tested according to the requirements of EN149:2001+A1:2009 standards, and the following items should be completed according to the actual situation:

01. Visual inspection:

Visual inspection should include markings and information provided by the manufacturer.

02. Packaging:

Sales packaging should be able to protect the product from mechanical damage and contamination before use.

Execution method: According to the requirements of Standard 8.2

03. Materials:

The materials used should be able to withstand handling and wear during the design and use period. Any semi mask used for particle protection should not have mechanical failure of the mask and strap. The mask should not deform. The substances released by the airflow passing through the mask should not cause harm or disturbance to the wearer

04. Practical performance:

Execution standard: According to the requirements of standard 8.4.

[Samples]

A total of 2 samples were tested, all of which were untreated samples

05. Finish of parts:

The parts that may come into contact with the wearer should have no sharp edges or burrs.

Execution standard: According to the requirements of standard 8.2

06. Total forward leakage:

【 Requirement 】

When using the TIL of each action as the evaluation basis (i.e. 10 people and 5 actions), at least 46 actions out of 50 actions have a TIL:

FFP1 ≤ 25%

FFP2 ≤ 11%

FFP3 ≤ 5%

When using the overall TIL of a person as the evaluation basis,

, Overall TIL of at least 8 out of 10 subjects:

FFP1 ≤ 22%

FFP2 ≤ 8%

FFP3 ≤ 2%

07. Penetration of filter material:

【 Requirement 】

Sodium chloride (95l/min), Paraffin oil (95l/min)

FFP1 ≤ 20% ≤ 20%

FFP2 ≤ 6% ≤ 6%

FFP3 ≤ 1% ≤ 1%

[Samples]

A total of 18 samples were tested, and 9 samples should be tested for each type of aerosol. Among them,

3 samples were untreated

3 samples, pre treated with simulated wearability in 8.3.1

3 samples, pre treated with 8.3.3 mechanical strength and 8.3.2 temperature adjustment

08. Compatibility with skin:

Materials that come into contact with the wearer's skin should not be considered as likely to cause irritation or have any other adverse effects on health.

Execution method: According to the requirements of standards 8.4 and 8.5

09. Flammability:

During the test, the mask does not burn or burns for no more than 5 seconds after the flame is evacuated.

Execution method: According to the requirements of standard 8.6

[Samples]

, a total of 4 samples were tested, of which:

2 were untreated samples

2 samples, pre treated with temperature adjustment in 8.3.2

8.3.2 Temperature Conditioning

a) Place in a dry environment at (703) ℃ for 24 hours B) Place at a temperature of (-303) ℃ for 24 hours

10. Carbon dioxide content of the inhalation air, also known as dead space, should not exceed 1% of the average value (by volume).

[Samples]

A total of 3 samples were tested, all of which were untreated samples 11. Head harness:

Execution method: According to standards 8.4 and 8.5

12. File of vision:

Execution method: According to standards 8.4

13. Breathing valve:

Only applicable to half masks with breathing valves

14. Breathing resistance:

[Requirement]

Classification maximum allowable resistance (mbar) 30 l/min for inhalation 95 l/min for exhalation 160 l/min

FFP1 0.6 2.1 3.0

FFP2 0.7 2.4 3.0

FFP3 1.0 3.0

1mbar=100Pa

15. Clogging:

For non reusable particle protection, half masks are optional, Half masks for reusable particle protection are mandatory

16. Removable parts:

All removable parts (if installed) should be easily connected and fixed by hand. The above article is a partial list. For more testing needs and details, please consult the online consultant of the free consulting agency: 152 0173 3840 (phone and WeChat). Doing testing on the top 100 inspection website - issuing authoritative testing reports has legal effect

For more related tests, please visit the official website of Baijian: Baijian. com

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

inspection and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China

Test report function

1、Project bidding: issue authoritative third-party CMA/CNAS qualification report;

2、E-commerce platform entry: quality inspection reports recognized by major e-commerce platforms;

3、Used as sales report: issuing a test report with legal effect to make consumers feel more at ease;

4、Papers and scientific research: providing professional and personalized testing needs;

5、Judicial services: providing scientific, fair and accurate testing data;

6、Industrial problem diagnosis: verifying the troubleshooting and correction of problems in industrial production;

Testing process

检测流程步骤

Detection advantages

检测优势

Related Recommendations

Service Hotline

Service Hotline

15601902607

WeChat
Baijian
Back to top
XBaijian

Screenshot, WeChat scan QR code

WeChat ID: 15601902607

(Click on WeChat ID, copy and add friends)

  Open WeChat

The WeChat ID has been copied, please open WeChat and add it for consultation details!