Consultation Hotline:400-101-7153
Contact Us/ CONTACT US
National free customer service telephone 400-101-7153

email:Service@Baijiantest.Com

phnoe:15601902607

telephnoe:400-101-7153

address:No. 700, Yishan Road, Xuhui District, Shanghai

Appliances & Insulation Products

AC measurement equipment (electromagnetic compatibility) testing

1、 ScopeThis standard is used to explain the unified inspection items and inspections of lamps produced by the company. This standard specifies the technical r...

To get tested, look for Baijian!

consultation hotline :400-101-7153

Mobile/WhatsApp:15601902607

test details

AC measurement equipment (electromagnetic compatibility) testingHow to apply for a report? What items need to be tested? We will conduct testing and evaluation in strict accordance with the standards. We can also provide personalized testing plans and reports according to your needs.

1、 Scope

This standard is used to explain the unified inspection items and inspections of lamps produced by the company. This standard specifies the technical requirements, experimental methods, inspection rules, marking methods, packaging, transportation, and storage conditions for LED lamps LED lamps refer to lighting fixtures that use LEDs as light emitting devices. Compared with traditional lamps that use high-pressure sodium lamps and metal halide lamps as light sources, they have advantages such as energy conservation and environmental protection

2. Reference basis:

"General Safety Requirements and Experiments for GB7000.1-2002D Luminaires"

"Measurement Methods for Integral LED Street Lamps"

"Housing Protection Level (IP Code) GB4028-93"

3 Inspection items: 1. Electrical performance parameters:

(1) Working voltage (2) Working current (3) Power (4) Power factor (5) Lamp safety level

(2) Optical parameters:

(1) Light intensity: Light intensity distribution curve, equal light intensity curve ⑵ Luminous flux: total luminous flux, effective luminous flux, regional luminous flux table, and annular luminous flux table ⑶ Illuminance: Illuminance distribution, isoilluminance curve ⑶ Light source: number of light sources, model of light source, composition of light source, and packaging of light source (4) Color temperature (5) Luminaire luminous angle

3. Structure and appearance:

⑴ Shell structure material ⑵ Type of lamp ⑶ Weight of lamp ⑶ Label of lamp ⑤ Protection level of lamp

4. Reliability experiment:

⑴ Temperature rise experiment ⑵ Switching electricity experiment ⑶ Vibration experiment ⑷ Luminescence maintenance characteristics and aging experiment.

Functional inspection of lighting fixtures

4. Inspection instructions: 1. Electrical parameters:

⑴ DC power supply lamps controlled by external power sources: voltage and current measured with voltage and ampere meters.

Attention: To measure the current, it is necessary to measure the current of a single LED lamp and a single color and record it.

⑵ For AC lamps with built-in power control, use a digital power meter to measure the voltage, current, power, power factor, and other parameters of the lamp ⑶ Class I lamps must undergo electrical strength, leakage current, and insulation resistance tests. The electrical strength is the breakdown phenomenon between the 220V terminal and the shell at 1500V and 1MIN. Leakage current ≤ 1.0MA. Insulation resistance ≥ 2M Ω The safety level of lighting fixtures can be divided into four types:

Class 0 lighting fixtures: ungrounded lighting fixtures that rely on basic insulation as protection against electric shock. This means that the easily accessible conductive parts of the lamp are not connected to the protective conductor in the fixed circuit of the facility, and in the event of basic insulation failure, they will have to rely on the environment Class I lamps: Ground wire lamps. The anti electric shock protection of lamps not only relies on basic insulation, but also includes additional safety measures, that is, connecting easily accessible conductive parts to the protective grounding conductor in the fixed line of the facility, so that easily accessible conductive parts do not become electrified in the event of basic insulation failure Class II lamps: ungrounded lamps, with electric shock protection not only based on basic insulation, but also with additional safety measures, such as double insulation or reinforcement, but without protective grounding measures or relying on installation conditions

Class III lighting fixtures: Lighting fixtures that rely on power supply voltage as a safe ultra-low voltage [AC voltage effective value less than 50V] for electric shock protection and do not generate * * SELV voltage

2. Optical performance parameters:

⑴ Light intensity: Light intensity distribution curve, equal intensity curve, and light intensity distribution data table can all be measured using a distribution photometer

⑵ Luminous flux: The total luminous flux and effective luminous flux are based on the test data of the spectral analysis system. The regional luminous flux table and the annular luminous flux table can be measured using a distribution photometer

⑶ Illuminance: Illuminance distribution and isoluminance curve can be measured using a distribution photometer (4) Color temperature: can be measured using a spectral analysis system

The above article is a partial list. For more testing needs and details, please consult the online consultant of the free consulting agency: 15201733840 (phone and WeChat), and conduct testing on the top 100 inspection websites. Issuing authoritative testing reports has legal effect

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

inspection and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China

Test report function

1、Project bidding: issue authoritative third-party CMA/CNAS qualification report;

2、E-commerce platform entry: quality inspection reports recognized by major e-commerce platforms;

3、Used as sales report: issuing a test report with legal effect to make consumers feel more at ease;

4、Papers and scientific research: providing professional and personalized testing needs;

5、Judicial services: providing scientific, fair and accurate testing data;

6、Industrial problem diagnosis: verifying the troubleshooting and correction of problems in industrial production;

Testing process

检测流程步骤

Detection advantages

检测优势

Related Recommendations

Service Hotline

Service Hotline

15601902607

WeChat
Baijian
Back to top
XBaijian

Screenshot, WeChat scan QR code

WeChat ID: 15601902607

(Click on WeChat ID, copy and add friends)

  Open WeChat

The WeChat ID has been copied, please open WeChat and add it for consultation details!